球探网官方主页

your location:

CPSII controller

Product introduction: CPSII controller adverbial machine tool electrical cabinet exterior, with KS06 type photoelectric protection device or KS06 cascade type photoelectric protection device, provides two relay passive contact outputs, standard configuration is two normally open outputs. The CPSII controller is equipped with a detection button to detect the self-test function of the system. CPSII controller function switch adopts double lock design to avoid potential safety hazards caused by misoperation or lock switch failure. The controller can provide two forms of single-sided protection and double-sided protection, and can provide two working modes of automatic reset and manual reset according to user requirements.

share to:

Features:

Compact appearance, convenient connection, stable performance, dedicated to bending machine

Typical wiring diagram:

CPSII Safety Controller Wiring Diagram
CPSII Safety Controller Wiring Diagram
Environmental characteristics
Ambient temperature jobs -10 ℃ ~ 55 ℃ (no frost and condensation)
storage -40 ℃ ~ 70 ℃
environment humidity jobs 35% RH to 85% RH
storage 35% RH ~ 95% RH
Protection class IP54
Dimensions 216 × 82 × 215mm
Electrical characteristics
voltage AC100V ~ 230V ± 15%, 50 / 60Hz DC24V ± 10%
Machine power consumption ≤15W
Output form OSSD1 / OSSD2 Two-way safety relay normally open contact output (standard)
OSSD3 / OSSD4 Two-way safety relay normally closed contact output (optional)
Output contact capacity 5A, AC250V / DC30V (resistive load)
Response time The whole machine (including the light curtain part) does not exceed 20ms
Insulation resistance > 100MΩ
Dielectric strength AC1500V, 60S without breakdown or flashover
Relay life > 1 million times (electrical life)
Matching light curtain KS06 photoelectric protection device KS06 Cascade Photoelectric Protection Device

CPSII Safety Controller Specifications
CPSII Dimension Drawing

Keli Optoelectronics Copyright 2018-2028 Website record number: Lu ICP No. 140080611-1