球探网官方主页

your location:

KS06Q type area photoelectric protection device

Product introduction: KS06Q area photoelectric protection device is divided into KS06QA series, KS06QB series and KS06QT series, of which KS06QT series is equipped with a special customized light curtain using a type of laser as the detection beam. The detection beam is emitted by the light emitter, and is reflected by the reflector and received by the light receiver. The light passing between the light emitter, the light receiver and the reflector forms a protective zone. KS06QA / KS06QB type zone protection device can be configured with CPSII controller installed outside the user electrical cabinet or CQ2 controller installed inside the user electrical cabinet. KS06QT type zone protection device can be configured with CPSV controller installed outside the user's electrical cabinet or CQ5 controller installed inside the user's electrical cabinet. The CPSV and CQ5 controllers are equipped with a collimation switch to control the opening of the collimated beam of the KS06T light curtain, which is convenient for field debugging. Both sets of relay contact signals can be provided to the user. The controller is equipped with two working modes: automatic reset and manual reset. When the photoelectric protection device is applied in the area protection, it is recommended to use the manual reset working mode. The CPSII / CPSV controller is equipped with a detection button to detect the self-test function of the system. In addition, the CPSII / CPSV controller function switch adopts a double lock design to avoid potential safety hazards caused by misoperation or failure of the lock switch.

share to:

Features

1. Long detection distance, can achieve multiple protections of single defense zone, two defense zones, three defense zones and four defense zones
2. The T series uses a class of laser products, which is safe for human eyes.
3. Can provide 4 area protection, simplify wiring and save costs
4.Strong ability to resist electromagnetic interference and light interference

Machine specifications

KS06Q type area photoelectric protection device specifications

Controller specifications

CPS controller specifications
CQ5 controller specifications

Controller technical parameters

Environmental characteristics
Ambient temperature jobs -10 ℃ ~ 55 ℃ (no frost and condensation)
storage -40 ℃ ~ 70 ℃
environment humidity jobs 35% RH ~ 85% RH
storage 35% RH ~ 95% RH
Protection class CPS V-type controller: IP54 CQ5 controller: IP20
Dimensions CPS V-type controller: 216 × 82 × 215mm CQ5 controller: 90 × 90 × 105mm
Electrical characteristics
voltage AC100V ~ 230V ± 15% 50 / 60Hz DC24V ± 10%
Machine power consumption ﹤ 15W
Output form Relay contact output
Output contact capacity 5A, AC250V / DC30V (resistive load)
Corresponding time ≤20ms
Insulation resistance ﹥ 100MΩ
Dielectric strength AC1500V, 60s without breakdown or flashover
Relay life ≥1 million times (electrical life)

Typical wiring diagram

CPSv controller wiring diagram
CPS V
CQ5 controller wiring diagram
CQ5

Security Level Type4 (gb / T19436)
Implementation standards GB / 19436.1; GB / T19436.2; GB4584-2007; IEC 61496-1; IEC 61496-2
Optical characteristics
Detection light source Infrared: KS06QA, KS06QB Laser: KS06QT
Protection height Optical axis distance × (beam number-1)
EAA <5 °
Optical axis distance 40mm 80mm 160mm 320mm Minimum 200mm can be sequentially increased by 50mm
Number of beams 4, 6, 8 ... 16 4, 6, 8 ... 16 4, 5, 6, 7, 8 3, 4, 5 2 ~ 8
protected range KS06QA: single defense zone: 20m; two defense zones: 14m; third defense zone: 10m; fourth defense zone: 8m KS06QB: single defense zone: 40m; two defense zones: 30m; third defense zone: 20m; fourth defense zone: 16m KS06QT: single defense zone: 150m; two defense zones: 120m; three defense zones: 80m; four defense zones: 60m
Environmental characteristics
Ambient temperature jobs -10 ℃ ~ 55 ℃ (no frost and condensation)
storage -40 ℃ ~ 70 ℃
environment humidity jobs 35% RH to 85% RH
storage 35% RH ~ 95% RH
Anti-light interference Incandescent light source 3000Lux
Fluorescent light source 3000Lux
Solar light source 10000Lux
EMC EMS Meet the requirements of GB / T19436-1 and GB4584-2007 for level 4 safety light curtain
EMI Meets the electromagnetic radiation requirements for industrial sites in EN61326-1 and EN55011
Anti-vibration Frequency 10Hz ~ 55Hz; Amplitude: 0.35 ± 0.05mm; Number of scans: three axes, 20 times per axis
Impact resistance Acceleration 10g; Pulse duration: 16ms; Number of collisions: three axes, 1000 ± 10 times per axis
Protection class IP65
Electrical characteristics
voltage DC12V ± 10%
Consumption current Illuminator ≤300mA
Receiver ≤100mA
Response time ≤20ms (whole machine, including controller)
Output characteristics Output square wave signal with frequency of 4kHz when passing light
Matching controller CPSII / CPSIII / CQ2 / CSRMC CPSV / CQ5
* KS06QA, KS06QB series optical axis spacing can be customized: 40 × N (N is an integer)

Number of beams KS06QA series / KS06QB series
Optical axis distance 40 Optical axis spacing 80 Beam pitch 160 Optical axis distance 320
Specifications Protection height Specifications Protection height Specifications Protection height Specifications Protection height
3 KS06Q * 0332 640
4 KS06Q * 0404 120 KS06Q * 0408 240 KS06Q * 0416 480 KS06Q * 0432 960
5 KS06Q * 0516 640 KS06Q * 0532 1280
6 KS06Q * 0604 200 KS06Q * 0608 400 KS06Q * 0616 800
7 KS06Q * 0716 960
8 KS06Q * 0804 280 KS06Q * 0808 560 KS06Q * 0816 1120
10 KS06Q * 1004 360 KS06Q * 1008 720
12 KS06Q * 1204 440 KS06Q * 1208 880
14 KS06Q * 1404 520 KS06Q * 1408 1040
16 KS06Q * 1604 600 KS06Q * 1608 1200
Note: * in the specification model indicates the light curtain series and the number of zones. For details, refer to the specifications of the whole machine. (Unit: mm)

H is the protection height, J is the length of the light emitter and the receiver, and L is the length of the ground protection cover (unit: mm)

Number of beams KS06QA series / KS06QB series
Optical axis distance 40 Optical axis spacing 80 Beam pitch 160 Optical axis distance 320
H J L H J L H J L H J L
3 640 799 960
4 120 239 400 240 399 560 480 639 800 960 1119 1280
5 640 799 960 1280 1439 1600
6 200 319 480 400 559 720 800 959 1120
7 960 1199 1280
8 280 399 560 560 719 880 1120 1279 1440
10 360 479 640 720 879 1040
12 440 559 720 880 1039 1200
14 520 639 800 1040 1199 1360
16 600 719 880 1200 1359 1520
KS06T area photoelectric protection device has a minimum optical axis spacing of 200mm, which can be increased by 50mm in sequence, and provides 2-8 detection beams at the same time

Installation mode of KS06Q area protection safety light curtain light curtain