球探网官方主页

your location:

CT4 safety light grid

Product introduction: TÜV-certified safety light curtain products with a safety level of Type 4 / EN / IEC 61496-1-2, Cat. 4 PL e / EN ISO 13849-1-2. The CT4 type safety grating can effectively detect any opaque objects that enter the detection area of the grating and exceed the detection accuracy. It is suitable for safety protection of mechanical presses, hydraulic presses, shears, bending machines and other dangerous places.

share to:

Features

1. TÜV safety certification, safety level reaches Type 4 Cat. 4 PL e
2. Small dead zone, saving installation space
3. IP65 / IP67 protection level, high protection ability
4. Clear surface anti-collision design, profile wall thickness is 3mm, strong anti-impact collision
5. The instructions are rich in information, the shunt instructions show the status of each beam, and it has the function of wiring self-test.
6. Internal and external vibration reduction design, good anti-vibration performance
7, high-strength bracket, multiple installation methods
8. Seeing "security", strong data supports MTTFD, MTTF, highly reliable security products

product composition

The CT4 safety light curtain system consists of a transmitter, a receiver and two transmission lines. The system works with DC24V, provides two PNP outputs, external equipment monitoring (EDM) function and one auxiliary output (non-safety), and is equipped with a status indication function. There are two types of detection distances: 8m and 15m. The detection accuracy is 14mm, 30mm and 46mm. The detection height is 232 mm to 1672 mm, and the extended accuracy is 120mm.

Appearance information

CT4 Safety Light Appearance Infographic

Specifications

CT4 safety light curtain system number
CT4 safety light curtain system number
CT4 type safety light curtain transmission line number
CT4 type safety light curtain transmission line number

Typical wiring diagram

CT4 safety light grid using EDM function wiring diagram
Wiring diagram using EDM function (Note: K1, K2: relays or other equipment controlling dangerous parts of the machine; K3: load or PLC (for monitoring). When K3 is not used, the CT4 encoder can work normally.)
CT4 safety light grid does not use EDM function wiring diagram
Wiring diagram without EDM function (Note: When EDM function is not used, EDM and AUX signals need to be shorted. K1, K2: relays or other equipment controlling dangerous parts of the machine; K3: load or PLC (for monitoring). When using K3, the CT4 grating can work normally.)

Technical Parameters
Implementation standards 2014/30 / EU (EMC Directive)
2006/42 / EC (Mechanical Safety Directive)
EN / IEC 61496-1 / -2 Type 4 ESPE
EN ISO 13849-1 / -2 Cat.4, PLe
EN / IEC 61326-1
ISO 13855
Optical characteristics
Detection light source Infrared LED (center wavelength 850nm)
Detection accuracy 14 mm 30 mm 46 mm
Detection distance A type: 0-8m Type B: 0-15m
Detection height 232 mm ~ 1672 mm (see the list of specifications and parameters of CT4 safety light grid)
Effective Aperture Angle (EAA) Meet the requirements of IEC61496-2, EAA <2.5 ° when the detection distance is above 3m
light source Infrared LED (wavelength 850nm)
Environmental characteristics
Ambient temperature jobs -10 ~ 55 ℃ (no frost and condensation)
storage -30 ~ 70 ℃
environment humidity jobs 35% ~ 85% RH
storage 35% ~ 95% RH
Environmental illuminance Incandescent 3000 Lux
Fluorescent lamp 3000 Lux
sunshine 10000 Lux
Protection class IP65, IP67 (IEC60529)
Anti-vibration ability Frequency 10 ~ 55Hz, amplitude 0.35 ± 0.05mm, 20 times each in X, Y and Z directions
Impact resistance Acceleration 100m / s2, pulse duration 16ms, 1000 times each in X, Y and Z directions
Dimensions 52 * 40 * Jmm (J is the length of the emitter and receiver)
Electrical characteristics
voltage DC 24 V ± 20% (ripple ± 5%)
Current consumption (without load) launcher < 200 mA
receiver < 200 mA
Response time 6 ms ~ 79 ms (see the list of CT4 safety light grid specifications and parameters)
Safety output (OSSD) PNP transistor output × 2
In the ON state, the load current is ≤300mA, and the output voltage is ≥Vcc-2V
In the OFF state, the leakage current is ≤1mA and the residual voltage is ≤1V (excluding the effect of lead extension)
Capacitive load: 0.9uF
Inductive load: 2H at 4Hz, can increase when the frequency decreases
Maximum transmission line length Transmitter: 50m; Receiver: 50m
Start Time <1s
Detection function Real-time self-test during power-on self-test
protect the circuit Over-voltage and over-current protection
Prevent mutual interference function Avoid light interference algorithm
Status indication launcher Power indicator: yellow, on when power is on and the system self-test is correct
Fault indication: red, on when fault occurs
Light-on indication: green, when the light is on and the output is ON, the light is on. At this time, the controlled equipment is allowed to run
Communication indication: blue, on when the signal between the transmitter and receiver is normally transmitted
receiver Power indicator: yellow, on when power is on and the system self-test is correct
Fault indication: red, when the grating system is faulty, the light is on. When EDM failure, communication failure, OSSD output failure and external light interference, the light flashes.
Light-off indicator: red, light-on when light-off or output OFF. At this time, the controlled equipment is not allowed to run
Light-on indication: green, when the light is on and the output is ON, the light is on. At this time, the controlled equipment is allowed to run
Additional features
Auxiliary output (AUX) Non-safety output, one PNP output, opposite to OSSD, output current ≤300mA in light-shielded state, voltage ≥Vcc-2V, output current in light-passed state <2mA, voltage <2V
External Equipment Monitoring (EDM) When external relay or contactor load, monitor the status of load normally closed contact
Input voltage in the ON state: 9V ~ 24V
OFF state input voltage: 0 to 7V or open circuit

List of specifications and parameters
Detection accuracy: 14mm Specifications Protection height (mm) Number of beams Response time (ms) MTTF D
(year)
PFH D
(1 / h)
MTTF (year) Dimensions (mm)
CT4 □ 0232P14G 232 30 <14 282 8.67E-09 45 52 × 40 × 264
CT4 □ 0352P14G 352 45 <19 231 1.08E-08 36 52 × 40 × 384
CT4 □ 0472P14G 472 60 <24 195 1.19E-08 32 52 × 40 × 504
CT4 □ 0592P14G 592 75 <30 169 1.50E-08 29 52 × 40 × 624
CT4 □ 0712P14G 712 90 <35 149 1.61E-08 26 52 × 40 × 744
CT4 □ 0832P14G 832 105 <41 133 1.87E-08 twenty four 52 × 40 × 864
CT4 □ 0952P14G 952 120 <46 120 2.03E-08 twenty two 52 × 40 × 984
CT4 □ 1072P14G 1072 135 <52 110 2.23E-08 twenty one 52 × 40 × 1104
CT4 □ 1192P14G 1192 150 <57 101 2.47E-08 19 52 × 40 × 1224
CT4 □ 1312P14G 1312 165 <62 94 2.74E-07 18 52 × 40 × 1344
CT4 □ 1432P14G 1432 180 <68 87 3.08E-08 17 52 × 40 × 1464
CT4 □ 1552P14G 1552 195 <73 81 3.08E-08 16 52 × 40 × 1584
CT4 □ 1672P14G 1672 210 <79 76 3.41E-08 15 52 × 40 × 1704
Detection accuracy 30mm CT4 □ 0232P30G 232 11 <7 394 5.94E-09 41 52 × 40 × 264
CT4 □ 0352P30G 352 16 <9 357 6.44E-09 39 52 × 40 × 384
CT4 □ 0472P30G 472 twenty one <11 326 7.04E-09 37 52 × 40 × 504
CT4 □ 0592P30G 592 26 <12 300 7.76E-09 36 52 × 40 × 624
CT4 □ 0712P30G 712 31 <14 278 8.67E-09 34 52 × 40 × 744
CT4 □ 0832P30G 832 36 <16 259 9.81E-09 33 52 × 40 × 864
CT4 □ 0952P30G 952 41 <18 243 9.81E-09 31 52 × 40 × 984
CT4 □ 1072P30G 1072 46 <20 228 1.08E-08 30 52 × 40 × 1104
CT4 □ 1192P30G 1192 51 <21 215 1.08E-08 29 52 × 40 × 1224
CT4 □ 1312P30G 1312 56 <23 203 1.19E-08 28 52 × 40 × 1344
CT4 □ 1432P30G 1432 61 <25 193 1.19E-08 27 52 × 40 × 1464
CT4 □ 1552P30G 1552 66 <27 184 1.33E-08 26 52 × 40 × 1584
CT4 □ 1672P30G 1672 71 <29 175 1.50E-08 25 52 × 40 × 1704
Detection accuracy: 46mm CT4 □ 0232P46G 232 7 <6 429 5.38E-09 43 52 × 40 × 264
CT4 □ 0352P46G 352 10 <7 402 5.94E-09 41 52 × 40 × 384
CT4 □ 0472P46G 472 13 <8 378 6.44E-09 40 52 × 40 × 504
CT4 □ 0592P46G 592 16 <9 357 6.44E-09 38 52 × 40 × 624
CT4 □ 0712P46G 712 19 <10 338 7.04E-09 37 52 × 40 × 744
CT4 □ 0832P46G 832 twenty two <11 321 7.04E-09 36 52 × 40 × 864
CT4 □ 0952P46G 952 25 <12 305 7.76E-09 35 52 × 40 × 984
CT4 □ 1072P46G 1072 28 <13 291 7.76E-09 34 52 × 40 × 1104
CT4 □ 1192P46G 1192 31 <14 278 8.67E-09 33 52 × 40 × 1224
CT4 □ 1312P46G 1312 34 <15 266 8.67E-09 32 52 × 40 × 1344
CT4 □ 1432P46G 1432 37 <16 256 9.81E-09 31 52 × 40 × 1464
CT4 □ 1552P46G 1552 40 <17 246 9.81E-09 30 52 × 40 × 1584
CT4 □ 1672P46G 1672 43 <19 237 1.08E-08 29 52 × 40 × 1704