SC6 Safety Carpet Controller

Product introduction: SC6 safety carpet controller is used in industrial safety systems, and can be used with safety carpets to enhance the reliability of equipment safety systems and form more secure protection systems.

share to:

Features

1. This controller is designed for linkage of safety carpet , which can drive up to 6 pieces
2. Each group of input signals has separate protection and non-protection function switches (suppression)
3, the indicator shows the working status of each safety carpet, including work, failure
4, with power indicator and output status indicator
5.Safety controller adopts DC24V power supply
6. One group of normally closed contact output, one group of normally open contact output
7, dual-channel operation mode, can complete the self-check of the safety carpet and controller
8.Manual reset and automatic reset can be switched
9, with a DC24V active alarm output, can detect the status of any piece of safety carpet in the system
10.Redundant circuits with self-monitoring in the circuit


SC6 safety carpet controller wiring method

Connect the four white, black, blue and brown wires of each safety carpet to the white, black, blue, and brown terminals of the controller according to the figure below. Connect the positive and negative electrodes of the 24V power supply to the controller's 24V + and 24V- Terminals, NO and NO are normally open outputs, NC and NC are normally closed outputs, and AL + and AL- are connected to the positive and negative poles of a 24V alarm, respectively. The reset is automatic reset when short-circuited. If it is changed to manual reset, it can add auto reset and normally open reset button. Standard length of 2-core power cable is 1.5m, standard length of 4-core output cable is 2m

sc6 safety carpet controller wiring diagram

Dimensions and installation instructions

SC6 type safety carpet controller uses Φ5.5 screws to install on the electrical cabinet or wall. Its dimensions are shown in the figure below.
sc6 safety carpet controller dimensions installation instructions

Suppression function
Guideline EN / IEC61496-1 (Type4 ESPE)
Implementation standards ISO 13849-1 (Cat.4); 2004/108 / EC (EMC Directive); 2006/42 / EC (Mechanical Safety Directive)
Ambient temperature jobs -10 ℃ ~ 55 ℃ (no frost and condensation)
storage -30 ℃ ~ 70 ℃
environment humidity jobs 35% RH to 85% RH
storage 35% RH ~ 95% RH
Anti-vibration ability Frequency 10 ~ 55Hz, amplitude 0.35 ± 0.05mm, 20 times each in X, Y and Z directions
Impact resistance 100m / s 2 acceleration, 16ms pulse duration, 1000 times each in X, Y and Z directions
Protection class IP50
voltage DC24V ± 10%
Power consumption ≤3W
Response time <20ms
Safety output 1 normally open 1 normally closed passive contact
load capacity AC15: 5A / 250V
DC13: 5A / 24V
Power-on startup time <1s
Detection function Power-on self-test
protect the circuit Over-voltage and over-current protection
Status indication POWER: red, on when power on
ERR: Red, lit when the carpet is faulty
ON: green, on when the output relay is closed
OFF: Red, on when the output relay is released
Dielectric strength AC1500V, 60s without breakdown or flashover
Implement function Real-time monitoring of safety carpets
Control output reset mode setting; alarm output reset mode setting
Suppression function
Relay life Electrical life: ≥1 million times
Mechanical life: ≥10 million times
Overall dimensions (mm) 156 × 142 × 32mm