球探网官方主页

your location:

CSRMF Safety Carpet Controller

Product introduction: CSRMF safety carpet controller is used in industrial safety systems, and can be used with safety carpets to enhance the reliability of equipment safety systems and form a more secure protection system.

share to:

Features

1.CSRMF safety carpet controller uses DC24V power supply
2, 1 group of normally closed contact output, 1 group of normally open contact output
3. Dual-channel operation mode, which can complete the self-check of carpet and controller
4, with power indicator and output status indicator
5, through the expansion module, you can increase the number of safety contacts
6.The output mode can be reset manually and automatically.
7, with a DC24V active alarm output, the output mode can be switched
8.Redundant circuits with self-monitoring in the circuit

Wiring

Connect the white, black, blue, and brown wires of the safety carpet to the white, black, blue, and brown terminals of the controller according to the figure below. COM and NC are normally closed contacts, and COM and ON are normally open contacts. R1 and R2 are automatically reset when short-circuited, and R1 and R2 are manually reset when disconnected. Standard 2-wire power cord 1.5m 4-core output wire standard 2-m



Guideline EN / IEC61496-1 (Type4 ESPE)
Implementation standards ISO 13849-1 (Cat.4); 2004/108 / EC (EMC Directive); 2006/42 / EC (Mechanical Safety Directive)
Ambient temperature jobs -10 ℃ ~ 55 ℃ (no frost and condensation)
storage -30 ℃ ~ 70 ℃
environment humidity jobs 35% RH to 85% RH
storage 35% RH ~ 95% RH
Anti-vibration ability Frequency 10 ~ 55Hz, amplitude 0.35 ± 0.05mm, 20 times each in X, Y and Z directions
Impact resistance 100m / s 2 acceleration, 16ms pulse duration, 1000 times each in X, Y and Z directions
Protection class IP50
voltage DC24V ± 10%
Power consumption ≤3W
Response time <20ms
Safety output 1 normally open 1 normally closed passive contact
load capacity AC15: 5A / 250V
DC13: 5A / 24V
Power-on startup time <1s
Detection function Power-on self-test
protect the circuit Over-voltage and over-current protection
Status indication POWER: yellow, on when power on
ERR: Red, lit when the carpet is faulty
ON: green, on when the output relay is closed
OFF: Red, on when the output relay is released
Dielectric strength AC1500V, 60s without breakdown or flashover
Implement function Real-time monitoring of safety carpets
Control output reset mode setting; alarm output reset mode setting
Relay life Electrical life: ≥1 million times
Mechanical life: ≥10 million times
Overall dimensions (mm) 110 × 100 × 24 (the size is 110 × 115 × 24 when the plug-in terminal block can be sealed without lock screws)

CSRMF-1A1B Safety Carpet Controller Number:
CSRMF-1A1B Safety Carpet Controller Numbering Diagram

Keli Optoelectronics Copyright 2018-2028 Website record number: Lu ICP No. 140080611-1